Flame-resistant breather membrane (WRB) for open-jointed cladding, gap width up to 35 mm (1 3/8”), with self-adhesive strips
Advantages
- Improved safety: 'not easily flammable', fire classification B-s1, d0 as per EN 13501-1
- Well-protected building structures: highly permeable and, at the same time, maximum protection against driving rain
- Not visible behind open-jointed cladding: black fleece with printed marking only in the overlap area
- Highest possible durability and thermostability thanks to the monolithic functional film
- 6 months of outdoor exposure
- Quick and reliable sealing thanks to the integrated ‘connect’ self-adhesive strips on the long strips of the membrane
Areas of application
For use as a breather membrane (weather-resistive barrier, WRB) behind closed and open facades (open-jointed cladding up to a gap width of 35 mm (1 3/8”); cladding width = at least 3 x gap width). Installation onto boarding, wood-based panels and all mat or panel-shaped thermal insulation materials.
Technical specs
| Material | |||
| Protective and covering fleece | Polypropylene microfibre | ||
| Functional film | Monolithic | ||
| Self-adhesive strips | Water-resistant SOLID adhesive | ||
| Property | Regulation | Value | Regulation |
| Colour | Black | ||
| Surface weight | EN 1849-2 | 145 g/m² ; 0.48 oz/ft² | EN 1849-2 |
| Thickness | EN 1849-2 | 0.5 mm ; 20 mils | EN 1849-2 |
| Water vapour resistance factor µ | EN ISO 12572 | 160 | EN ISO 12572 |
| sd value | EN ISO 12572 | 0,08 m | EN ISO 12572 |
| g value | 0.4 MN·s/g | ||
| Vapour permeance | ASTM E 96 | 41 perms | ASTM E 96 |
| Fire class | EN 13501-1 | B‑s1, d0 | EN 13501-1 |
| Outdoor exposure | 6 months | ||
| Watertight joints with ‘connect’ adhesive strips or TESCON VANA tape | EN 13859-1 | W1 | EN 13859-1 |
| Water column | EN ISO 811 | 10 000 mm; 32' 10" | EN ISO 811 |
| Watertightness, non-aged/aged* | EN 13859-2 | W1 / W1 | EN 13859-2 |
| Tensile strength MD/CD | EN 13859-2 (A) | 260 N/5 cm / 225 N/5 cm ; 30 lb/in / 26 lb/in | EN 13859-2 (A) |
| Tensile strength MD/CD, aged* | EN 13859-2 (A) | 260 N/5 cm / 220 N/5 cm ; 30 lb/in / 25 lb/in | EN 13859-2 (A) |
| Elongation MD/CD | EN 13859-2 (A) | 60 % / 80 % | EN 13859-2 (A) |
| Elongation MD/CD, aged* | EN 13859-2 (A) | 30% / 40% | EN 13859-2 (A) |
| Nail tear resistance MD/CD | EN 13859-2 (B) | 190 N / 220 N ; 43 lbf / 49 lbf | EN 13859-2 (B) |
| *) Durability after artificial ageing | EN 1297 / EN 1296 | Passed (for walls with open joints) | EN 1297 / EN 1296 |
| Flexibility at low temperature | EN 1109 | ‑40 °C ; ‑40 °F | EN 1109 |
| Temperature resistance | EN 1109, EN 1296, EN 1297 | Permanent ‑40 °C to 80 °C ; ‑40 °F to 176 °F | EN 1109, EN 1296, EN 1297 |
| Thermal conductivity | 0.04 W/(m·K) ; 0.3 BTU·in/(h·ft²·°F) | ||
| CE labelling | EN 13859-2 | Yes | EN 13859-2 |